Fisher
3051S
Rosemount 3051S pressure transmitter with WirelessHART
The scalable platform in its wireless version, for pressure, flow and level.
Pressure · Rosemount
Pressure where there used to be only an operator round: remote points, wells and auxiliary equipment, with no conduit and no cable.
It is the same pressure measurement, by radio instead of cable, for points where wiring is expensive or unfeasible: remote facilities, auxiliary equipment, additions to an existing plant and variables that today are only read on the round.
Rosemount 3051S and 3051 transmitters with WirelessHART run on their own power module and send the value to a gateway. The Wireless Pressure Gauge replaces the mechanical gauge, keeps a readable dial and transmits as often as once per minute.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
3051S
The scalable platform in its wireless version, for pressure, flow and level.
Fisher
3051
The standard transmitter with a WirelessHART output and no signal wiring.
Fisher
2051
Optional WirelessHART for fast deployment in remote areas.
Fisher
Wireless Pressure Gauge
Replaces the mechanical gauge: solid-state sensor, local dial and data over WirelessHART.
Fisher
Smart Pressure Gauge
The same benefits as the wireless gauge, without the WirelessHART protocol.
Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
Each instrument joins a WirelessHART network and transmits its measurement and diagnostics to the gateway. The update rate is configurable and determines power module life: the more often it reports, the shorter the life.
The wireless gauge removes the mechanical components that wear out. According to the manufacturer it offers up to 10 years of maintenance-free operation, overpressure protection of up to 150 times and two layers of process isolation. The dial also indicates device status.
The wireless 3051S and 3051 measure gauge, absolute and differential pressure with the same sensor and the same mountings as their wired versions.
A gauge with a solid-state sensor and local dial that transmits the reading over WirelessHART.
The same rugged gauge, without a radio, for points that only need reliable local indication.
The WirelessHART gateway collects the data from the network and delivers it to the system; the power module supplies each instrument.
Applications
ITS de Venezuela
We quote new Rosemount transmitters, gauges, gateways and power modules, configure the network and commission the instruments in the field, calibrate them through our calibration service, in the field and in the laboratory, and integrate the data into the control or monitoring system. We reply with availability in Venezuela or Orlando. To quote, send the pressure type and range, fluid, process connection, number and location of points, desired update rate and the system the data must reach.
Quote parts or repairPressure, temperature, flow and volume, in the field and in the laboratory.
On-site support, shutdowns, commissioning and start-up.
Loops, actuation, re-engineering and equipment upgrades.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Gauge, absolute and differential transmitters.
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
It has no Bourdon tube, links or gears: it measures with a solid-state pressure sensor. According to the manufacturer it offers up to 10 years of maintenance-free operation and overpressure protection of up to 150 times, and it also transmits the reading over WirelessHART.
That is what the Rosemount Smart Pressure Gauge is for: the same gauge with a solid-state sensor, without the WirelessHART protocol.
Pressure

Gauge, absolute and differential pressure, Coplanar or in-line, with HART, fieldbus or wireless.

Isolation, equalization and venting of the transmitter in one compact block, assembled and tested with it.

Remote seals and electronic remote sensors to measure where the transmitter cannot touch the fluid.

Level from hydrostatic head, in open and pressurized tanks, with seals or remote sensors.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.