Fisher
2625
Fisher 2625 volume booster
Used with a positioner on throttling valves to increase stroking speed.
Positioners and instruments · Fisher
A control valve is an assembly: besides the positioner, these accessories decide its speed, its position signal and its failure action.
They are the instruments that, alongside the positioner, complete the control valve assembly: they move more air to shorten the stroke, report position, condition the supply air or impose a defined action if that supply fails.
The volume booster sits between the positioner and the actuator: when the signal changes sharply it quickly delivers a large volume of air and, when the change is slow, its integral bypass restriction leaves fine control to the positioner.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
2625
Used with a positioner on throttling valves to increase stroking speed.
Fisher
VBL
Fixed deadband, soft seats and an integral bypass restriction to avoid positioner saturation.
Fisher
4400
Non-contact position feedback, with a 4-20 mA signal and on/off indication.
View bulletin
Fisher
377
Pressure-sensing: if supply falls below the trip point, the actuator fails up, fails down or locks in place.
Fisher
67CFR
67C Series instrument supply regulator, with filter and internal relief.
Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
The booster takes the positioner output as its signal. While that signal changes slowly, air passes through the bypass restriction and steady-state accuracy is governed by the positioner. On a large, fast change, the booster opens its main port and moves air directly to or from the actuator. The bypass adjustment sets the balance between speed and stability.
The FIELDVUE 4400 position transmitter senses travel with no mechanical contact with the stem and provides a 4-20 mA signal with on/off indication; it is calibrated with local pushbuttons and communicates over HART. The 377 trip valve monitors supply pressure: when it falls below the trip point, it causes the actuator to fail up, fail down or lock in its last position, and it resets automatically when pressure recovers.
They increase the stroking speed of throttling valves and keep steady-state accuracy through their integral bypass restriction.
It senses the position of rotary or sliding-stem valves, vents and dampers and reports it to the control system; it is digital and linkage-less, with two solid-state limit switches.
For applications that require a specific valve and actuator action when supply pressure falls below an adjustable point. A single valve covers the three failure modes.
Direct-operated regulators, with or without a filter, that provide a constant, reduced pressure to pneumatic and electro-pneumatic instruments; the 67CFR includes a filter and internal relief.
Applications
ITS de Venezuela
We quote Fisher volume boosters, position transmitters, trip valves and supply regulators, with their genuine repair kits (diaphragms, seats and O-rings), and build the complete assembly on the actuator. In our Puerto Ordaz workshop and in the field we adjust the booster bypass, calibrate the transmitters and test the failure action; when the assembly carries a FIELDVUE instrument, we verify the response with ValveLink. Parts are managed through the Venezuela ↔ Orlando inventory. For a quotation, send the actuator model and size, the installed positioner, the supply pressure, the required stroking time and the failure action.
Quote parts or repairConfiguration, diagnostics and commissioning of controllers and instruments.
Pressure, temperature, flow and volume, in the field and in the laboratory.
Loops, actuation, re-engineering and equipment upgrades.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Positioners, FIELDVUE digital controllers and valve instruments.
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
When the positioner alone does not move enough air to meet the stroking time: large actuators, long supply lines and fast loops. The booster delivers a large volume of air on sharp signal changes and, through its bypass restriction, leaves fine control to the positioner.
So that the control system knows the actual valve position through an independent signal, useful for monitoring and interlocks. The FIELDVUE 4400 provides it with no mechanical contact with the stem, as a 4-20 mA signal with on/off indication.
Positioners and instruments

The instrument that positions the valve and also diagnoses it: it evaluates the performance and health of the assembly without shutting down the process.

They deliver air to the actuator until stem or shaft position matches the set point, with a pneumatic or 4-20 mA signal.

They close the loop in the field: they measure the variable, compare it with the set point and send the corrective signal to the final element.

They measure and control liquid level, the interface between two liquids or density with a displacer sensor, in pneumatic, electric or digital versions.

They convert the 4-20 mA electrical signal into a proportional pneumatic pressure: the link between the electronic loop and the air-operated valve.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.