Fisher
DSV1000
Fisher Digital Isolation DSV1000 full-bore ball valve solution
Three-piece, trunnion-mounted, full-bore ball valve designed for isolation service.
Process and isolation · Fisher
The final element of a safety function: a ball valve that hardly restricts flow when open and an actuation package tested to close when the system commands it.
It is a quarter-turn valve whose closure member is a sphere with a bore of the same diameter as the pipe: when open, the fluid passes practically unrestricted; when closed, the seats seal against the solid face of the ball.
The Fisher DSV1000, three-piece and trunnion-mounted, is intended for safety instrumented systems. It is delivered as a Digital Isolation solution: valve, actuator, FIELDVUE DVC6200 SIS controller and accessories, tested as one unit.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
DSV1000
Three-piece, trunnion-mounted, full-bore ball valve designed for isolation service.
Fisher
DVC6200 SIS
Controls the safety shutdown function and runs the partial stroke test of the assembly.
View bulletin
Fisher
2625
Accessory that increases air flow to the actuator when fast stroking is required.
Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
In a trunnion-mounted design the ball turns on two fixed supports, top and bottom, which absorb the thrust of line pressure. The seats bear on the ball instead of carrying it, so operating torque stays under control as size and pressure grow, exactly where a floating ball would demand a much larger actuator.
In an SIS, the valve is part of the final element of a safety instrumented function together with the actuator and the controller. The actuator, normally a spring-return pneumatic scotch yoke, drives the valve to its safe position on loss of signal or air. The DVC6200 SIS controls that closure and allows partial stroke testing: it moves the valve a few degrees with the process running and checks that it is not stuck.
The body splits into a center section and two ends, giving access to the ball and seats for maintenance.
The ball bore matches line diameter: minimum pressure loss with the valve open.
Emerson presents these solutions with Bettis scotch yoke pneumatic actuators (G-Series, CBA300 and CBB), with the failure position defined by the process.
FIELDVUE DVC6200 SIS with partial stroke testing and, depending on the required closing speed, volume boosters, supply regulators and limit switches.
Applications
ITS de Venezuela
ITS quotes the Fisher Digital Isolation DSV1000 solution and the genuine parts of the assembly (valve seats and seals, actuator parts, controller and accessories), and provides field service for installed assemblies: mounting and calibration of the DVC6200 SIS, partial stroke test setup and diagnostics with ValveLink, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: line size and pressure class, fluid, pressure and temperature, maximum pressure drop with the valve closed, failure position, required closing time, available air pressure and, if applicable, the SIL of the function.
Quote parts or repairConfiguration, diagnostics and commissioning of controllers and instruments.
On-site support, shutdowns, commissioning and start-up.
Valve condition assessment before deciding to repair or replace.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Ball, butterfly, gate, check and automatic recirculation.
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
In a floating design the ball rests on the seats and line pressure pushes it against the downstream seat; it is simple and suited to moderate sizes and pressures. In a trunnion-mounted design the ball turns on fixed supports that absorb that thrust, so torque stays under control in large sizes and high pressures.
It is a maneuver in which the controller moves the safety valve a fraction of its travel, with the process running, and returns it to position. It checks that the valve and actuator are not stuck and records pressure and position to detect friction changes or leaks. It allows full stroke tests, which require stopping the process, to be spaced out.
Process and isolation

Friction-free metal seating in a compact quarter-turn body, assembled with actuator and digital controller for safety instrumented systems.

Eccentric disc and pressure-assisted seal: tight shutoff in a compact, light body, for large lines in on-off or throttling service.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.