Fisher
JOS-E
Crosby Style JOS-E pressure relief valve
Conventional spring-loaded, full-nozzle construction for gas, vapor and steam service.
Relief and safety · Crosby
A spring, a disc and a full nozzle: the most widely used overpressure protection on process vessels and lines, in conventional, bellows and balanced diaphragm versions.
A spring-loaded pressure relief valve holds a disc closed against a nozzle with the force of a calibrated spring. When pressure overcomes that force, it opens, discharges to a safe system and recloses below set pressure, with no signal, air or power.
The Crosby J-Series is the process family: one design for air, gas, steam, liquid and two-phase service, with a full nozzle, interchangeable parts and adjustable blowdown. Its standardized API 526 orifices make it easier to replace valves of the same designation.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
JOS-E
Conventional spring-loaded, full-nozzle construction for gas, vapor and steam service.
Fisher
JBS-E
Balanced bellows version for variable back pressure or fluids that must be kept out of the bonnet.
Fisher
JLT-JOS-E
Liquid trim on the conventional construction: stable opening in incompressible service.
Fisher
JLT-JBS-E
Liquid trim with balanced bellows, for discharge into headers with back pressure.
Fisher
JDS-E
Balanced diaphragm instead of a metal bellows: more back pressure margin, according to the manufacturer.
Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
In compressible service the valve pops open: as the disc lifts, the fluid acts on a larger area and drives it to full lift with little overpressure. An adjusting ring on the nozzle tunes that effect and sets the blowdown, the difference between set pressure and reseating pressure. On liquids a dedicated trim is used that opens proportionally and stays stable, without chatter.
Back pressure at the outlet is the variable that decides the construction. In a conventional valve it acts on the disc and shifts the opening pressure; a bellows or a balanced diaphragm isolates the spring side and holds set pressure even when back pressure changes, as happens when discharging into a shared flare header.
Closed bonnet with the spring exposed to discharge pressure. For discharge to atmosphere or to systems with low, constant back pressure.
A metal bellows compensates for variable back pressure and isolates the spring and guide from the discharged fluid, useful with corrosive or fouling products.
Internals designed for incompressible service, on the conventional or the bellows construction, with stable opening and defined capacity on liquids.
Replaces the bellows with a diaphragm. According to Emerson it extends the back pressure limit to 80% of set pressure and is available as a conversion kit for installed J-Series valves.
Applications
ITS de Venezuela
ITS quotes new Crosby J-Series valves and their genuine parts (springs, discs, nozzles, bellows, guides and gaskets), and looks after installed valves within its regulators and relief service: inspection, maintenance, set pressure adjustment and bench testing in the Puerto Ordaz workshop, with field service during turnarounds and the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data (if you do not have it, a photo of the nameplate helps identify the valve): style and inlet and outlet size, orifice letter, set pressure, fluid, temperature and back pressure at the outlet.
Quote parts or repairMaintenance of pressure regulators and relief devices.
Valve condition assessment before deciding to repair or replace.
On-site support, shutdowns, commissioning and start-up.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Safety and pressure-relief valves (PSV/PRV).
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
When back pressure at the outlet is variable or high, for example when discharging into a header shared with other valves. In a conventional valve that back pressure adds to the spring force and shifts the opening pressure; the bellows or the balanced diaphragm compensates for it. It is also used to isolate the spring from corrosive or fouling fluids.
The nameplate data: style, inlet and outlet size, orifice letter, set pressure and, if shown, the back pressure and design temperature. With that data and the fluid, an equivalent valve or the parts for the existing one can be quoted. If the nameplate is not legible, a photo of the valve and the service conditions make it possible to identify it.
Relief and safety

Direct spring safety valves for boiler and process steam, set and tested on steam, with two-ring control of set pressure and blowdown.

Compact, economical overpressure protection for thermal relief and small-size services, with a single trim for liquid, gas and vapor in Series 900.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.